DN(IV)                       3/20/74                       DN(IV)
NAME
     dn - DN-11 ACU interface
DESCRIPTION
     The dn?  files are write-only.  The permissible codes are:
         0-9  dial 0-9
         :    dial *
         ;    dial #
         -    4 second delay for second dial tone
         =    end-of-number
     The entire telephone number must be presented  in  a  single
     write system call.
     It is recommended that an end-of-number code be  given  even
     though not all ACU's actually require it.
FILES
     /dev/dn0        connected to 801 with dp0
     /dev/dn1        not currently connected
     /dev/dn2        not currently connected
SEE ALSO
     dp (IV)
BUGS